DREXO

Alarms

Understanding alarm types, severity, and the tracker widget.

Alarms

An alarm is an abnormal state raised by a device — e.g. a leak, a blocked meter, or an out-of-range temperature. Drexo tracks each alarm's state over time: when it was raised, when it was resolved, how many devices are affected.

The page slug stays /alarmes in both locales so the language switcher round-trips cleanly. The content here is the English source of truth.

Where to see alarms

Four surfaces, by depth:

  • Top-bar badge — the ⚠ N pill on the right, clickable, leads to the full page.
  • Alarms page — full-screen view of every active alarm, sorted by type.
  • "Alarms" widget — pinnable on any of your personal dashboards.
  • Device page — active alarms + transition history for that single meter.

All these surfaces read the same source of truth and are RLS-scoped: you only ever see alarms for devices you already have access to.

The /alarmes page

Drexo Alarms page with the type pane on the left and the device pane on the right
The /alarmes page: left pane lists active alarm types (with affected-device counts), right pane lists devices in that state.

Two side-by-side panes:

  • On the left, the list of active alarm types in your scope, with the number of affected devices next to each. Sorted by severity desc: leaks at the top, informational alarms at the bottom.
  • On the right, for the type selected on the left, the list of devices currently in that state. Each row shows:
    • the contextual device name,
    • the raised-at date,
    • recent metrics (24h, 7d, current index),
    • a direct link to the page.

At the top of the page, the Pin widget on selector lists your personal dashboards. Tick those that should display the same view — the widget becomes visible on as many boards as you want (the pin is per-dashboard, the alarm state itself is unique).

Alarm types

Itron Intelis wSource meters report about a dozen types. Drexo groups them by severity:

High severity

Recommended action: act quickly.

  • Leak (previous day) — continuous consumption for 24 h with no meaningful pause.
  • Backflow (previous day) — reverse flow detected.
  • Broken pipe — persistent state. Drexo keeps it raised until the meter explicitly reports the resolution.
  • Blocked meter — the wheel isn't turning despite expected demand.
  • Magnetic tamper — a magnet was detected near the sensor.
  • Removed meter — the device has been dismounted or uncoupled.
  • Battery — low level reported by the meter itself.

Medium severity

Recommended action: monitor, schedule a visit.

  • Peak flow (previous day) — hourly spike above threshold.
  • Air in pipe (previous day) — air bubbles detected.
  • High / low temperature (previous day) — out of normal range.
  • Scaling — the meter's internal computation.
  • Battery (estimated) — not a direct meter signal, estimated by Drexo from behaviour.

Low severity

Information, not urgency.

  • High / low monthly volume — threshold breach on last month's total.
  • Reserved meter — inventory flag.
  • NFC credit — payment / authorisation event.

Alarm lifecycle

  1. The meter emits a LoRaWAN frame with the flag raised.
  2. Drexo receives the frame via n8n + InfluxDB and writes a row into eau_alarms (table is append-only — no silent modification possible).
  3. The alarm appears instantly across every surface listed above.
  4. When the meter later emits a frame without the flag, Drexo writes a "resolved" transition into the same table.
  5. The device page surfaces that transition in the history.

Alarms are never modified retroactively: if you see a "Leak" alarm raised yesterday morning and resolved this morning, both rows remain in the history even after the event.